Understanding Dimensional Reference Temperature on a Technical Drawing
A dimensional reference temperature specifies the temperature at which stated geometrical or dimensional requirements apply. The standard reference in ISO 1 is 20 °C. The applicable drawing can specify a different reference. This is the condition to which a reported size should correspond.
Specification Reference vs. Measurement Conditions
It is important to distinguish between two related but separate concepts:
For a drawing that specifies a diameter at 20 °C, the tolerance applies to the size at that reference temperature. A reading at another temperature can still be used if the temperature effects are evaluated appropriately.
Record the actual part and measuring-system conditions. A suitable thermal correction estimates the size at the reference temperature. Use a representative expansion coefficient and account for uncertainty in the temperature, coefficient and instrument response.
Thermal Correction Assumptions
When a part is measured away from the reference temperature, a thermal correction may be applied using the material's coefficient of linear thermal expansion, along with the temperature differential and the nominal dimension. Several assumptions underlie this kind of correction, and they should be stated plainly rather than implied:

Cosmetic packaging samples on display in a showroom.
- The material is assumed to be thermally stable and fully equilibrated to the measurement environment, not still cooling from a molding or finishing process.
- The coefficient of thermal expansion used is assumed to be representative of the actual resin lot, filler content, or alloy composition, which can vary from generic published values.
- A simple linear correction assumes expansion adequately described by the coefficient and measurement direction. Constraint, gradients or anisotropy can require a different model.
- Any correction is assumed to apply only within a modest temperature range; large deviations from the reference condition introduce nonlinear effects that a simple linear correction will not capture accurately.
Uncertainty Considerations
Conformance is decided using the specified tolerance, corrected measurement if required, its uncertainty and the applicable decision rule. Temperature effects enter the measurement model. They do not create a new drawing tolerance.
Applicable Drawing Requirements
Check the drawing and applicable standards for the reference temperature and any separate conditioning requirements.
A Hypothetical Illustration
Suppose a hypothetical molded tube has a 15.00 mm bore referenced to 20 °C. A corrected instrument reading for the bore at an equilibrated part temperature of 28 °C is 15.012 mm. If the applicable linear expansion coefficient is assumed to be 0.00010 per °C, the estimated size at 20 °C is about 15.000 mm. The correction is illustrative and its uncertainty must still be evaluated.