Peak Shaving Battery Storage: How It Works, Benefits and System Sizing

Estimated read time 4 min read

What Is Peak Shaving Battery Storage?

Peak shaving battery storage helps commercial and industrial facilities reduce their maximum electricity demand from the grid by using stored energy during high-demand periods.

Factories, warehouses, and commercial buildings often experience electricity demand peaks when multiple electrical systems operate simultaneously. Where electricity tariffs include demand charges, these peaks can increase operating costs.

Commercial battery energy storage systems (BESS), such as the RENAC RENA5000, help businesses manage these fluctuations through intelligent battery charging and discharging.

How Does Battery Peak Shaving Work?

A peak shaving battery system supplies stored electricity when facility demand increases, reducing the power drawn from the grid.

The process involves three stages:

1. Monitor Electricity Demand

An Energy Management System (EMS) monitors electricity consumption, battery status, and operating conditions.

2. Discharge During Demand Peaks

When grid demand approaches a configured threshold, the battery discharges to supply part of the facility's electricity requirements.

3. Recharge During Lower-Demand Periods

The battery recharges when electricity demand decreases, electricity prices are favorable, or surplus solar energy is available.

This coordinated operation helps businesses manage electricity demand without significantly changing normal operations.

How to Size a Battery for Peak Shaving

Battery sizing depends on two factors: power (kW) and energy capacity (kWh).

  • Power (kW): Determines how much peak electricity demand the battery can reduce.

  • Energy Capacity (kWh): Determines how long the battery can provide the required power.

Consider a factory with the following demand:

Parameter Value
Maximum Electricity Demand 500kW
Target Grid Demand 400kW
Required Battery Power 100kW
Peak Duration 1 Hour
Required Usable Energy Approximately 100kWh

In this example, the battery must supply approximately 100kW for one hour to reduce grid demand from 500kW to 400kW.

For example, the RENAC ESS-261 provides 125kW rated power and 261kWh nominal battery capacity.

For facilities requiring approximately 100kW of peak demand reduction, this configuration could be a suitable option, subject to actual load profiles, usable battery capacity, system efficiency, and operating limits.

This demonstrates how battery power and energy capacity should be evaluated together when selecting a commercial energy storage system.

Key Benefits of Peak Shaving Battery Storage083a5c103b0211da99a46fbc72af0e38

Reduce Peak Demand Charges

Battery storage can help reduce maximum grid demand and potentially lower electricity costs where demand-based tariffs apply.

Improve Energy Management

Intelligent battery operation allows businesses to manage fluctuating electricity demand more efficiently.

Increase Solar Self-Consumption

For facilities with solar PV installations, batteries can store surplus solar electricity for later use.

Support Time-of-Use Optimization

Commercial batteries can also charge during lower-price periods and discharge when electricity prices increase.

Actual savings depend on local electricity tariffs and operating conditions.

RENAC RENA5000: Commercial Battery Storage for Peak Shaving

The RENAC RENA5000 C&I Battery Energy Storage System combines an all-in-one design, modular configuration, and intelligent energy management.

Its ESS-261 battery storage cabinet features:

Specification Details
Rated Power 125kW
Nominal Battery Capacity 261kWh
Battery Technology LFP
System Design All-in-One
Energy Management Intelligent EMS

The system supports peak shaving, time-of-use electricity management, and solar energy integration.

With intelligent EMS control, battery charging and discharging can be coordinated according to facility electricity demand and operating requirements.

For existing solar PV installations, AC-coupled battery storage can also allow compatible original PV inverters to remain in operation, simplifying system upgrades.

These capabilities make RENA5000 a potential solution for factories, commercial buildings, and industrial facilities seeking more flexible electricity management.

Is Peak Shaving Battery Storage Worth It?3c1835e760d7497bca246e00578fe7ee

The financial value of battery peak shaving depends on electricity tariffs, demand patterns, equipment costs, and operating conditions.

Facilities with high demand charges and predictable electricity peaks may benefit from battery storage.

Before selecting a system, businesses should analyze historical electricity consumption and evaluate the expected savings against total project costs.

Conclusion

Peak shaving battery storage offers businesses a practical way to reduce grid demand peaks and improve electricity management.

With intelligent EMS control, 125kW / 261kWh battery storage, and flexible system integration, the RENAC RENA5000 C&I BESS supports commercial and industrial energy management applications.

Selecting the right system starts with understanding facility electricity demand and defining clear operating objectives.

Explore Commercial & Industrial Energy Storage Solutions:

https://www.renacpower.com/

https://www.renacpower.com
RENAC Power

You May Also Like

More From Author

+ There are no comments